Skip to content

SRMFA Case Study – Toshiba 1000hp Reweld

Ref. #:
456200
Date:
June, 2018
Make:
Toshiba
Nameplate:
1000 HP \ 4160 VAC \ 885 RPM

Job Description

Rotor was exhibiting excessive vibration and taken out of service due to corrosion related to H2S gas exposure.

Testing and Assessment

There were several areas of highly visible corrosion at the bar-to-end-ring interface. SRMFA testing revealed several broken and damaged rotor bars. Due to the severity of the damage, this rotor was sandblasted and rewelded at Brandon & Clark’s facility in Lubbock, TX.

Corrosion from H2S Gas Exposure

SRMFA Test Results

Available Downloads